Text Box:                        HEATING
Text Box: MANUFACTURER: Lennox                       EST. AGE: 29 years     ORIG. LIFE SPAN:   20 years 
FUEL TYPE:  NAT. GAS   X    L.P. GAS       ELECT.      SOLAR       SOLID FUEL       OTHER
UNIT TYPE: FORCED AIR  X   GRAVITY       BOILER      HEAT PUMP      CONVECTION       
UNIT SIZE: GAS  100,000 BTU/HR         ELECT   Kw/hr             
FURNACE LOCATION: BSMT  X  MECHANICAL ROOM     CRAWL SPACE     ATTIC   GARAGE    
PLENUM/TRUNK MATERIAL: STEEL   X   FIBERGLASS     PLASTIC     CONCRETE       
BRANCH  DUCT  MATERIAL: STEEL   X   FIBERGLASS     PLASTIC     CONCRETE       
 

Text Box: FURNACE (S)                                                                          MAIN PLENUM
Text Box: 0  l  0  0  0  l

Text Box: l  0  0  0  0  0

Text Box: DUCT TRUNK                                                                        BRANCH DUCTS
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: SUPPLY AIR   141 F.                                                          RETURN AIR   67 F.
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: BURNERS                                                                              PILOT ASSEMBLY
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: FAN/MOTOR                                                           CO TEST (EQUIP./VENT)
Text Box: l  0  0  0  0  0

Text Box: 0  0  0  0  0  l

Text Box: VENT                                                                              VENT. CONNECTOR
Text Box: 0  l  0  0  0  l

Text Box: 0  0  l  0  0  l

Text Box: EQUIP. CLEARANCE                                                       COMB. AIR SUPPLY
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: GAS SUPPLY                                                                                    AIR FILTER
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: CIRCULATING PUMP                                                       HYDRONIC PIPING
Text Box: 0  0  0  l  0  0

Text Box: 0  0  0  l  0  0

Text Box: EXPANSION TANK                                             ELECTRICAL DISCONNECT
Text Box: 0  0  0  l  0  0

Text Box: l  0  0  0  0  0

Text Box: UV AIR PURIFIER                                                                           HUMIDIFIER
Text Box: 0  0  0  l  0  0

Text Box: 0  0  0  l  0  0

Text Box: AREAS OF CONCERN                                                                                                                            

Text Box: NATIONAL  BUILDING  CONSULTANTS  •  P.O. BOX 4172 • TOPEKA, KANSAS  66604  •  785.232.2701 • RalphNBC@cox.net 
 
Typical Condition

Marginal

Poor/Unsafe

Not Applicable

Not Checked

Comments
Text Box: Comments: The furnace in the basement has a limited life based on the age of the furnace. Past back-drafting, smoke damage, and corrosion was noted in the combustion chamber and heat exchanger. Due to the age and condition of the furnace an additional inspection and a water-test of the heat-exchanger should be performed. The vent connector does not maintain the proper clearance to combustible material. Install Type “B” double-wall vent pipe where the vent passes through the perforated wall board into the crawlspace. Create the required one inch air space between the Type “B” vent pipe and combustible materials where it passes through the wall and install a metal firestop around the vent pipe. Install a listed wind-cap above the roof to prevent back-drafting that was noted at the furnace.

Text Box: SERVICE FURNACE/BURNERS             
NO ELECTRICAL DISCONNECT                              
INSUFFICIENT COMBUSTION AIR       
                        

Text Box: IMPROPER AIR TEMPERATURES
UNIT IMPROPERLY CYCLED
IMPROPER VENT CLEARANCE         X
 
                       

Text Box: CORROSION NOTED ON VENT
IMPROPER VENT  TERMINATION      ASBESTOS MATERIAL NOTED          

Typical Condition

Marginal

Poor/Unsafe

Not Applicable

Not Checked

Comments