Text Box: AIR CONDITIONING
Text Box: MANUFACTURER: Carrier                   EST. AGE  09 yrs                 ORIG. LIFE SPAN 20 yrs
FUEL TYPE:  NAT. GAS     L.P. GAS      ELECT.    X     SOLAR     THERMAL STORAGE        
UNIT TYPE:  CENTRAL SPLIT SYSTEM  X    HEAT PUMP       GEOTHERMAL     PORTABLE    
UNIT SIZE: 30,000 BTU/hr    AMPACITY RATING: 14.8AMP   MAX. CIRCUIT PROTECTION: 30AMP  
PLENUM/TRUNK MATERIAL: STEEL   X   FIBERGLASS     PLASTIC     CONCRETE       OTHER
BRANCH  DUCT  MATERIAL: STEEL  X   FIBERGLASS      PLASTIC     CONCRETE       OTHER
 

Text Box: CONDENSER UNIT                                                        CONDENSER COILS
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  l

Text Box: FAN MOTOR                                                                           SERVICE LINES
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: DISCONNECT                                                              ELECT. CONDUCTOR
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: SUPPLY AIR  42 F                                                                RETURN AIR  58 F
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: DUCT TRUNK                                                                        BRANCH DUCTS
Text Box: l  0  0  0  0  0

Text Box: CONDENSATE LINE                                                     CONDENSATE PUMP
Text Box: l  0  0  0  0  0

Text Box: 0  0  0  l  0  0

Text Box: FAN/MOTOR                                                               AIR SPEED/QUANTITY
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box: FILTER                                                                      CONDENSATE DAMAGE
Text Box: l  0  0  0  0  0

Text Box: 0  0  0  l  0  0

Text Box: PROPER OUTLET                                                                  MISC CONTROLS
Text Box: l  0  0  0  0  0

Text Box: l  0  0  0  0  0

Text Box:                                                                                                                                                                                  

Text Box: RUST ON COIL CABINET                     
NOT ABOVE ADJACENT GRADE     
COILS BLOCKED WITH DEBRIS            
 

Text Box: IMPROPER BREAKER/FUSE SIZE                  X   
SERVICE LINE  SEALANT/CAULKING       
CONDUCTOR REQUIRES CONDUIT    

CONDENSATE DAMAGE

DUCT INSULATION REQUIRED      

ASBESTOS MATERIAL NOTED         Text Box: CONDENSATE DAMAGE
DUCT INSULATION REQUIRED       
ASBESTOS MATERIAL NOTED        

CONDENSATE DAMAGE

DUCT INSULATION REQUIRED      

ASBESTOS MATERIAL NOTED        

Text Box: Typical Condition

Marginal

Poor/Unsafe

Not Applicable

Not Checked

Comments
Typical Condition

Marginal

Poor/Unsafe

Not Applicable

Not Checked

Comments
Text Box: AREAS OF CONCERN

Text Box: Comments: The air conditioning system produced the recommended 15F-21F air temperature drop across the evaporator coil. Reduce the 30amp breaker serving the condenser unit circuit with a 25amp breaker. Caulk around the service lines where they enter the house, as needed. Clean the debris from the condenser unit coils twice during each cooling season. Utilize aluminum-backed tape or a brush-on compound to seal all joints of the ducts and the evaporator coil cabinet.

Text Box: l  0  0  0  0  0

Text Box: NATIONAL  BUILDING  CONSULTANTS  •  P.O. BOX 4172 • TOPEKA, KANSAS  66604  •  785.232.2701 • RalphNBC@cox.net